page contents
 jenny@greennb.com     0574-58220818

Product Category

Hot-Selling Products

loading

Share to:
sharethis sharing button

GREEN GTHX Series Fresh Air Ventilator

Model: Fresh air ventilator
Type:Vertical / Horizontal / Ceiling / Small single skin panel type / Small intelligent type
Rated airflow:200m3/h~18000m3/h
Model Number: Customize
Key Selling Points: Famous brand component
Availability:
Quantity:
  • GTHX2Q-GTHX(X)180

  • GREEN

 

fresh air ventilator



      Model: Fresh air ventilator

      Type:Vertical / Horizontal / Ceiling / Small single skin panel                       type/Small intelligent type

      Rated airflow:200m3/h~18000m3/h

      Model Number: Customize                        

      Key Selling Points: Famous brand component        



Performance data

Model


Rated airflow
(m3/h)


ESP
(pa)


Power
(W)


Current
(A)


Noise     dB(A)


Cooling efficiency (%)

Heating efficiency (%)

Weight     (Kg)


Dimension       (with flange)
(mm)


Flange size
(mm)


Temp.

efficiency

%

Enthalpy

Efficiency

%

Temp.

Efficiency

%

Enthalpy

Efficiency

%

GTHX2Q

200

75

65

0.5

30

77

64

78

69

25

848X654X264

Φ144

GTHX3Q

300

75

120

0.6

45

78

65

78

70

27

926X722X270

Φ144

GTHX4Q

400

80

200

1.0

48

78

65

79

70

30

926X722X270

Φ144

GTHX5Q

500

80

220

1.0

50

79

66

79

71

41

1018X1027X270

Φ194

GTHX6Q

600

90

242

1.2

50

79

65

79

70

42

1018X1027X270

Φ194

GTHX8Q

800

100

410

1.5

52

79

65

79

70

68

1274X1007X388

Φ242

GTHX10Q

1000

130

510

2.0

54

78

67

78

71

82

1274X1007X388

Φ242

GTHX13Q

1300

150

913

4.1

54

78

67

78

70

82

1287X1257X388

Φ242

GTHX15Q

1500

160

1028

4.4

58

78

67

78

72

82

1287X1257X388

Φ242

GTHX15Q

1500

160

1028

4.4

58

78

67

78

72

82

1287X1257X388

Φ242

Note:  

1.The power supply adopts 220V/1P/50Hz.

2.The noise is measured in a semi-muffled sound chamber. Under actual conditions, due to environmental condition, the noise value may be larger than the marked value.

3. The above performance improved without prior notice.


Model


Rated airflow
(m3/h)


ESP
(pa)


Power
(W)


Summer

Winter

Noise                   dB(A)


Power supply


Temp.efficiency %

Enthalpy efficiency %

Temp.efficiency %

Enthalpy efficiency %

GTHX(X)3.0DS

300

50

0.022-4P

70.3

72.2

69.5

60.2

43.5

220V/1PH/50HZ







GTHX(X)4.0DS

400

60

0.12-4P

69.6

71.5

68.7

59.3

43.3

GTHX(X)6.0DS

600

128

0.075-4P

70.3

72.2

69.5

60.1

46.1

GTHX(X)8.0DS

800

111

0.10-4P

66

68.1

65

54.9

56

GTHX(X)10DS

1000

150

0.15-4P

64.5

66.7

63.5

53.1

57.5

GTHX(X)12.5DS

1250

161

1.5-4P

64

66.2

63

52.6

57.7

GTHX(X)15DS

1500

200

0.2-4P

63.7

65.9

62.7

52.2

60.5

Note:                                                                                                                                                                                             1.Summer: Fresh air temperature: 35/21(DB/WB), humidity 26%; air return temperature: 24/17(DB/WB), humidity: 50%.

2.Winter: Fresh air temperature: 3(DB), humidity: 50%; air return temperature: 24(DB), humidity: 50%.


Model


Rated airflow
(m3/h)


ESP
(pa)


Power
(W)


Summer

Winter

Noise                   dB(A)


Power supply


Temp.efficiency %

Enthalpy efficiency %

Temp.efficiency %

Enthalpy efficiency %

GTHX(X)16D

1600

140

0.32 x 2

66

68.4

65

54.1

57.3

380V/3PH/50HZ








GTHX(X)20D

2000

160

0.45 x 2

65

67.3

63.8

52.3

62

GTHX(X)25D

2500

250

0.45 x 2

65

67.4

63.8

51.8

63.2

GTHX(X)30D

3000

260

0.8 x 2

66.1

68.6

65.1

53.1

64.4

GTHX(X)40D

4000

280

1.1 x 2

66.1

68.5

65

53.6

69.4

GTHX(X)50D

5000

250

1.5 x 2

64.3

66.8

63.6

51.9

72

GTHX(X)60D

6000

230

1.5 x 2

67.1

69.4

66

54.8

73.8

GTHX(X)80D

8000

230

2.2 x 2

64.8

67.1

65.1

58.1

75.2

Note:                                                                                                                                                                                             1.Summer: Fresh air temperature: 35/21(DB/WB), humidity 26%; air return temperature: 24/17(DB/WB), humidity: 50%.

2.Winter: Fresh air temperature: 3(DB), humidity: 50%; air return temperature: 24(DB), humidity: 50%.


Model


Rated airflow
(m3/h)


ESP
(pa)


Power
(W)


Summer

Winter

Noise                   dB(A)


Power supply


Temp.  efficiency

%

Enthalpy            efficiency                      

%

Cooling capacity       (kw)

Temp.

efficiency      

%

Enthalpy  

Efficiency

%

Cooling

capacity

(kw)

GTHX(X)16D

1600

145

0.32+0.45

66

68.4

12.2

65

54.1

33.47

57.3

380V/3PH/50HZ








GTHX(X)20D

2000

172

0.45+0.45

65

67.3

15.68

63.8

52.4

42.18

62

GTHX(X)25D

2500

252

0.45+0.8

65

67.4

18.96

63.8

51.8

51.4

63.2

GTHX(X)30D

3000

263

0.8+0.8

66.1

68.6

23.53

65.1

53.1

63.05

64.4

GTHX(X)40D

4000

283

1.1+2.2

66.1

68.5

29.01

65

53.6

74.74

69.4

GTHX(X)50D

5000

249

1.5+1.8

64.3

66.8

36.51

63.6

51.9

92.57

72

GTHX(X)60D

6000

236

1.5+1.8

67.1

69.4

44.69

66

54.8

112.24

73.8

GTHX(X)80D

8000

281

2.2+2.2

64.8

67.1

59.03

65.1

58.1

146.63

75.2

Note:                                                                                                                                                                                             1.Summer: Fresh air temperature: 34.6/20.4(DB/WB), humidity 26%; air return temperature: 24/17.5(DB/WB), humidity: 50%, coil inlet/outlet temperature:6/12

2.Winter: Fresh air temperature: 3(DB), humidity: 50%; air return temperature: 24(DB), humidity: 50%, coil inlet/outlet temperature:80/60.


Model


Rated airflow
(m3/h)


ESP
(pa)


Power
(W)


Summer

Winter

Noise                   dB(A)


Power supply


Temp.efficiency %

Enthalpy efficiency %

Temp.efficiency %

Enthalpy efficiency %

GTHX(X)40L

4000

190

1.1 x 2

65.6

67.8

64.7

55.1

64.9

380V/3PH/50HZ








GTHX(X)50L

5000

190

1.1 x 2

64.2

66.2

63.2

54

73.7

GTHX(X)60L

6000

180

1.5 x 2

64.7

66.7

63.7

54.7

73.8

GTHX(X)80L

8000

250

2.2 x 2

65.9

67.8

64.9

56.4

75.2

GTHX(X)100L

10000

230

3 x 2

66.1

68.2

65.1

55.6

77

GTHX(X)120L

12000

400

4 x 2

66.6

68.7

65.6

56.1

76.1

GTHX(X)150L

15000

400

6 x 2

66.9

69

65.9

56.5

76.2

GTHX(X)180L

18000

400

7.5 x 2

66.9

69

65.9

56.5

78.9

Note:                                                                                                                                                                                             1.Summer: Fresh air temperature: 35/21(DB/WB), humidity 26%; air return temperature: 24/17(DB/WB), humidity: 50%.

2.Winter: Fresh air temperature: 3(DB), humidity: 50%; air return temperature: 24(DB), humidity: 50%.

Model


Rated airflow
(m3/h)


ESP
(pa)


Power
(W)


Summer

Winter

Noise                   dB(A)


Power supply


Temp.efficiency %

Enthalpy efficiency %

Temp.efficiency %

Enthalpy efficiency %

GTHX(X)40W

4000

190

1.1 x 2

65.6

67.8

64.7

55.1

69.4

380V/3PH/50HZ








GTHX(X)50W

5000

190

1.1 x 2

64.2

66.2

63.2

54

73.7

GTHX(X)60W

6000

180

1.5 x 2

64.7

66.7

63.7

54.7

73.8

GTHX(X)80W

8000

250

2.2 x 2

65.9

67.8

64.9

56.4

75.2

GTHX(X)100W

10000

300

3 x 2

69.9

71.9

69.1

60.69

77

GTHX(X)120W

12000

500

4 x 2

71.2

73.1

70.3

62.1

76.1

GTHX(X)150W

15000

500

6 x 2

71.2

73

70.3

62

76.2

GTHX(X)180W

18000

550

7.5 x 2

71

72.9

61.8

56.5

78.9

Note:                                                                                                                                                                                             1.Summer: Fresh air temperature: 35/21(DB/WB), humidity 26%; air return temperature: 24/17(DB/WB), humidity: 50%.

2.Winter: Fresh air temperature: 3(DB), humidity: 50%; air return temperature: 24(DB), humidity: 50%.









Main Features


  • Total heat recovery heat exchanger: the core adopts imported high-quality total heat exchange paper as heat and moisture transfer conductor, which has the characteristics of high moisture permeability, good air tightness, tear resistance, aging resistance and high heat transfer rate.This kind of heat exchanger is mainly used in the area with small temperature difference between indoor and outdoor and high humidity.


  • Sensible heat recovery heat exchanger: the core adopts high quality hydrophilic coating aluminum foil resistant to seawater as heat transfer conductor. It is processed by special process, with high heat exchange efficiency, easy maintenance and long life. This kind of heat exchanger is especially suitable for the area with large temperature difference between indoor and outdoor and the low humidity.


Previous: 
Next: 

ABOUT US

NEWS

PRODUCTS

CONTACT US

  131-5748-5116
     0574-58220818
  jenny@greennb.com
Copyright © 2020 Ningbo Green Air-conditioner Science&Technology Co., Ltd.